Built-In Functions

Jim's Image Fitting has several built-in fit functions for some of the more common fitting procedures. You can set up Image Fitting to perform one of these fits by selecting appropriate tab:

The tabs for the built-in fitting functions

These are the built-in functions:

T2/R2

T2 or R2 estimation from MR sequences with different echo times (TE). Enter the TE values in milliseconds. The T2 will be estimated in milliseconds. This is also used to estimate T2* or R2* if you have acquired gradient-echo images rather than spin-echo.

The tab for the T2/R2 fitting function

Output parameters: M0 and T2 or R2

Select Check-box to create R2 rather than T2 parameter maps if you want to produce an R2 parameter map, rather than a T2 map.

By default, T2 maps will be created with units of milliseconds, and R2 maps with units of milliseconds-1. Select Check-box to create parameter maps with units of seconds rather than seconds^-1 if you want to produce parameter maps with units of seconds or seconds-1.
Note: be sure to select Check box to make sure that output images are always in floating-point format if either of the above options is selected, since images with integer intensities cannot store the parameter values with sub-integer accuracy.

In order place limits on the large fitted parameter values that can occur due to noise in the images, you may want to enter the maximum physically feasible T2 value here: Limiting the maximum allowed fitted T2 value. In vivo T2 values do not normally exceed 3 seconds. The minimum T2 is automatically limited to zero.

SR T1/R1

Saturation-recovery T1 or R1 estimation from MR sequences with different repetition times (TR) (time between the 90° excitation pulses). Enter the TR values in milliseconds. The T1 will be estimated in milliseconds.

The tab for the saturation-recovery T1/R1 fitting function

Output parameters: M0 and T1 or R1

Select Check-box to create R1 rather than T1 parameter maps if you want to produce an R1 parameter map, rather than a T1 map.

By default, T1 maps will be created with units of milliseconds, and R1 maps with units of milliseconds-1. Select Check-box to create parameter maps with units of seconds rather than seconds^-1 if you want to produce parameter maps with units of seconds or seconds-1.
Note: be sure to select Check box to make sure that output images are always in floating-point format if either of the above options is selected, since images with integer intensities cannot store the parameter values with sub-integer accuracy.

You can place limits on the large fitted parameter values that can occur due to noise in the images, by entering the maximum physically feasible T1. The minimum T1 is automatically limited to zero.

FLASH T1/R1

T1 or R1 estimation from FLASH sequences with different flip angles (alpha). Enter the alpha values in degrees and enter the (constant) TR value (in milliseconds). The T1 will be estimated in milliseconds.

The tab for the FLASH T1/R1 fitting function

Output parameters: M0 and T1 or R1

Select Check-box to create R1 rather than T1 parameter maps if you want to produce an R1 parameter map, rather than a T1 map.

By default, T1 maps will be created with units of milliseconds, and R1 maps with units of milliseconds-1. Select Check-box to create parameter maps with units of seconds rather than seconds^-1 if you want to produce parameter maps with units of seconds or seconds-1.
Note: be sure to select Check box to make sure that output images are always in floating-point format if either of the above options is selected, since images with integer intensities cannot store the parameter values with sub-integer accuracy.

You can place limits on the large fitted parameter values that can occur due to noise in the images, by entering the maximum physically feasible T1. The minimum T1 is automatically limited to zero.

MRI scanners may not produce accurate flip angles for their RF pulses, so the flip angles you enter may need to be scaled with a scaling factor that depends on position in the image. This can achieved using a flip angle calibration method, which produces an image of the flip angle scaling factor needed. In regions where the flip angle calibration is correct, the scaling factor image would have a value of 1.0; in regions where the actual flip angle is lower than the nominal value, the scaling factor image would have a value less than 1.0; in regions where the actual flip angle is greater than the nominal value, the scaling factor image would have a value greater than 1.0. If you want to correct the flip angle in this way, select Check-box to use a flip-angle calibration image and the select the flip angle calibration image:

Select the image that contains the flip angle calibration

IR T1/R1

Inversion-recovery T1 or R1 estimation from phase-sensitive or absolute-value MR sequences with different inversion times (TI) (time between the 180° inversion pulse and the excitation pulse). Enter the TI values in milliseconds. The T1 will be estimated in milliseconds.

The tab for the Inversion-Recovery T1/R1 fitting function

Output parameters: M0 and T1 or R1

Select Check-box to create R1 rather than T1 parameter maps if you want to produce an R1 parameter map, rather than a T1 map.

By default, T1 maps will be created with units of milliseconds, and R1 maps with units of milliseconds-1. Select Check-box to create parameter maps with units of seconds rather than seconds^-1 if you want to produce parameter maps with units of seconds or seconds-1.
Note: be sure to select Check box to make sure that output images are always in floating-point format if either of the above options is selected, since images with integer intensities cannot store the parameter values with sub-integer accuracy.

You can place limits on the large fitted parameter values that can occur due to noise in the images, by entering the maximum physically feasible T1. The minimum T1 is automatically limited to zero.

The Fitter can fit to either phase-sensitive IR images (with both positive and negative pixel intensities), or absolute value (magnitude) images. If you are working with magnitude images, select Check-box to specify that inversion-recovery images are absolute value, rather than phase-sensitive.

MOLLI T1/R1

Modified Look-Locker Inversion-Recovery (MOLLI) T1 or R1 estimation from phase-sensitive or absolute-value MR sequences with different inversion times (TI). This is similar to IR T1/R1 above, except that there is an additional fitted parameter (B) to allow for the fact that the longitudinal magnetization is perturbed by the train of read-out pulses. fitting function">

The tab for the MOLLI T1/R1 fitting function

Output parameters: M0, B (scaled by a factor of 1000) and T1 or R1

ADC

Apparent diffusion coefficient (ADC) estimation from diffusion-weighted images with different b-factors. Enter the b-factors in seconds per square millimetre. The ADC will be estimated in microns2/second.

The tab for the apparent diffusion coefficient fitting function

Output parameters: M0 and ADC

You can place limits on the large fitted ADC values that can occur due to noise in the images, by entering the maximum physically feasible ADC value. The minimum ADC is automatically limited to zero.

If you have suggestions for more built-in fitting functions to include, please mail them to Contact Xinapse Systems support.